Industrial Cable

MYSO CABLES PVC insulated L. T. Light Duty Cables are as per IS: 694 and are suitable for fixed wiring and flexible operations. The cables are suitable for use on AC single-phase or three-phase (earthed or unearthed) systems for rated voltage up to and including 1100 volts. 

CONDUCTOR: The most acceptable metals for conductors are copper and aluminum due to their higher conductivity and ductility. As copper has got a higher affinity for sculpture, it corrodes in the atmosphere where sulfur fumes are present. In these conditions tinned copper should be used.

Myso Single core PVC Unsheathed/Sheathed Cables with Copper/Aluminium Conductor in voltage grade upto 1100 volts

Area Sq. mm

No. & Size of Wire Nominal mm

Max. Res. 200oC Ohm/Km

Current Carrying Capacity Amps.

Unsheathed

Sheathed

Solid

Strard

Copper

Allu.

Copper

Allu.

Insulation Thickness Nominal mm

Overall Diameter Max. mm

Insulation Thickness Nominal mm

Sheath Thickness Nominal mm

Overall Diameter Maximum mm

1.0

1/1.12

 

18.10

 

11

8

0.7

3.20

0.6

0.8

4.71

1.5

1/1.38

3/0.82

12.10

18.10

14

10

0.7

3.40

0.6

0.8

5.01

2.5

1/1.78

3/1.06

7.41

12.10

19

15

0.8

4.20

0.7

0.8

5.84

4.0

1/2.24

7/0.85

4.61

7.41

26

20

0.8

4.80

0.8

0.9

6.81

6.0

1/2.74

7/1.06

3.08

4.61

35

27

0.8

5.60

0.8

0.9

7.81

10.0

1/3.55

7/1.40

1.83

3.08

44

34

1.0

7.00

1.0

0.9

8.31

16.0

7/1.70

1.15

1.91

55

43

1.0

8.20

1.0

1.0

10.51

25.0

7/2.14

0.727

1.20

75

58

1.2

10.00

1.2

1.1

12.51

35.0

7/2.50

0.524

0.868

90

70

1.2

11.50

1.2

1.1

13.51

50.0

7/3.00

0.385

0.641

120

92

1.4

13.00

1.4

1.2

15.51

70.0

19/2.14

0.268

0.443

150

116

1.4

15.00

95.0

19/2.50

0.193

0.320

175

135

1.6

17.50

120.0

37/2.03

0.153

0.253

200

155

1.6

19.00

150.0

37/2.24

0.124

0.206

230

175

1.8

21.00

185.0

37/2.50

0.0991

0.164

265

205

2.0

23.50

240.0

37/2.85

0.0754

0.125

315

245

2.2

26.50

 

Myso Single core heavy duty Flexible cables generally in accordance with – is : 694 – 1990 voltage grade upto 1100 volts

 

Area Sq. mm

25.0

35.0

50.0

70.0

95.0

120.0

150.0

185.0

240.0

CONDUCTOR

No. & Sizes of Wires Nominal mm

196/.4

276/.4

396/.4

360/.05

475/.5

608/.5

750/.5

925/.5

1221/.5

Max. Resistance@20oC Ohm/Km

0.780

0.554

0.386

0.272

0.206

0.161

0.129

0.106

0.0801

Current Rating DC/AC Amps

80

102

138

214

254

300

340

390

460

INSULATION

Thickness
mm

1.2

1.2

1.4

1.8

1.9

2.1

2.1

2.5

2.5

Overall Diameter mm

11.0

12.5

14.5

17.0

19.0

21.0

23.5

26.0

29.5